The most expensive mistake in a smart home is finding out after the renovation that the cables weren't run, the switch boxes aren't deep enough, or the curtain box is too narrow. By then the only options are hacking walls, taking down the ceiling, or settling for less.
That's why, before every project starts, we ask the designer, the contractor and the homeowner to sign a site coordination letter (one in Chinese and one in English, so every tradesman on site can read it) that fixes exactly what has to be prepared. Below are the 8 items in that letter that are most often missed. Just go through them with your wireman, carpenter and air-con technician.
The whole list in one table
| # | What to prepare | Who does it |
|---|---|---|
| 1 | Run neutral + live to every switch point; switch boxes at least 5 cm deep | Electrician |
| 2 | Use a ganged box for switches in a row, or keep two boxes 88 mm apart, centre to centre | Electrician |
| 3 | Make the motorised curtain box wide enough (straight track: single ≥10 cm, double ≥20 cm) | Carpenter |
| 4 | Motorised curtains and presence sensors need permanent power that doesn't go through a switch (live and neutral both present) | Electrician |
| 5 | Put smart lights and non-smart lights on separate circuits; a circuit over 400 W needs an AC contactor | Electrician |
| 6 | Leave permanent power at the smart air-con controller position; nothing blocking the IR controller's line to the air-con | Electrician, air-con technician |
| 7 | Use Cat6 or Cat6A network cable, all run back to the low-voltage box (45 × 35 × 15 cm, ideally with a fan) | Electrician |
| 8 | Gas detector 1.5–3 m horizontally from the hob; leave a socket 30 cm below the ceiling | Electrician |
1. Switch points: why a neutral wire, and why a 5 cm deep box?
A smart switch needs power for itself. A smart switch with a neutral wire (live + neutral) has a steady power supply and works with any light, without flickering. Without a neutral, you can only use a single-live-wire switch, and LED lights may flicker or glow faintly when switched off.
The problem is that many Malaysian homes only run the live wire to the switch point, while the neutral goes straight to the light. So before renovation, tell your electrician:
- Leave neutral, live and switched (light control) wires at every switch point
- Use a standard 86-type switch box, at least 5 cm deep
- No more than 3 light control wires in one box
- After wiring, fit a dust cover so cement and skim coat don't fall into the box
- Don't put smart lights and non-smart lights on the same circuit: keep them separate
Two-way switching: smart switches link to each other wirelessly, so the two-way wires aren't connected. We still recommend running them as shown on the design drawing, so it's easier to make changes later.
Full-screen panels (the kind with a screen): put an 86-type box where the homeowner wants it, also 5 cm deep, with neutral and live.
2. Several switches in a row
- Use a ganged box for the neatest result
- If you use single boxes, keep them 88 mm apart, centre to centre
- On walls with a finish (for example stone or wood panelling), cut a 60 × 60 mm opening in the finish
3. How wide should a motorised curtain box be?
If the curtain box is too narrow, the track won't fit. The minimum widths in the coordination letter:
| Track | Single layer | Double layer |
|---|---|---|
| Straight track | ≥ 10 cm | ≥ 20 cm |
| L-shaped track | ≥ 20 cm | ≥ 30 cm |
| Custom-shaped track (anything other than straight or L-shaped) | ≥ 25 cm | ≥ 35 cm |
Motorised roller blinds: the blind box should be wider than 15 cm and 15 cm deep, with a power cable run into the box.
4. Power for the curtain motor
The curtain motor needs permanent power that doesn't go through a switch, with both live and neutral. Choose one of the following, as shown on the design drawing:
- A socket: place it 45 cm below the finished curtain box, within the area the curtain covers, so it's hidden once the curtain is drawn. If the track is mounted on the window sill, don't put the socket too close to the window; leave room for the window installation
- Cable end only: no socket faceplate; leave the power cable in the curtain box
5. Presence sensors
A presence sensor (it detects whether anyone is in the room, to switch the lights on and off automatically) needs permanent power that doesn't go through a switch, with both live and neutral, and a 55 mm round cut-out.
6. Smart air-conditioning
- Ducted units (the IR-controlled type): leave dedicated permanent power at the air-con controller position. Nothing should block the line between the controller and the air-con, or the infrared signal won't reach it
- VRF central air-con: leave power at the indoor unit's access panel
- For VRF systems connected to a smart controller: run one communication cable from each outdoor unit's communication port (terminals such as F1/F2, X/Y, P/Q) to the smart control cabinet, and label both ends with the outdoor unit number. Use 0.5 mm² 2-core sheathed cable. Leave power and a network port in the control cabinet
- Leave permanent power that doesn't go through a switch at the thermostat position too
- Power cable specifications and socket types follow our design drawings and coordination letter; go through them item by item with your electrician before work starts
7. Network cable and the low-voltage box
- Use Cat6 or Cat6A pure copper network cable
- Run every AP's cable back to the same low-voltage box, and keep the fibre modem, router and network switch in that box too. Label every cable in the box with where it goes
- Leave a network point in every space (except bathrooms and the kitchen)
- Ceiling-mounted APs: leave the cable in the false ceiling, and reinforce the mounting spot during renovation
- Wall-mounted 86-type APs: put the box at the same height as the socket, side by side
- Low-voltage box 45 × 35 × 15 cm (length × width × depth), ideally with a cooling fan
- When we design, we place at least one gateway on every floor, so every room responds quickly
8. Gas detector
- Don't install it directly above the hob
- Keep it 1.5–3 m horizontally from the hob, away from the kitchen cabinets
- Leave power 30 cm below the ceiling (or integrated ceiling panel)
Other items (as shown on the drawing)
- Dimmable downlights and spotlights: for each lighting circuit, run one 0.5 mm² 3-core sheathed cable together with that circuit's live and neutral, looping from the first light to the last. Leave 30 cm at each cut-out; it doesn't need to go back to the switch. The 0.5 mm² refers to this 3-core cable; size the live and neutral according to electrical standards
- Projector screen: the screen box is usually ≥ 15 cm deep, with a power cable run into the box
- Cameras: leave power where the homeowner wants them
- More than 400 W of lights on one circuit (bulbs and LED strips combined): install an AC contactor. Run the smart switch's control wire to the contactor; the lights' power is switched through the contactor, not directly by the smart switch. Mount the contactor in the nearest distribution board (DB), with space left on the DIN rail
Who signs the coordination letter, and who is responsible if something goes wrong?
- Signed by three parties: the designer, the contractor and the homeowner
- The design firm is responsible for making sure the site is finished according to the design drawings
- Any extra construction cost is agreed between the homeowner and the contractor in advance
- If anything comes up on site, ask us directly or raise it in the renovation group chat
FAQ
Can I install smart switches without a neutral wire?
You can use single-live-wire switches, but LED lights may flicker or glow faintly when off. If you haven't renovated yet, the easiest way is to have your electrician leave a neutral at every switch point.
Can you do a home that's already renovated?
Usually, yes. Wireless systems (Bluetooth Mesh) don't need new network cabling, which makes them a good fit for renovated homes. We first check whether the switch boxes have a neutral wire and are deep enough. Send us photos of a few switch boxes and we'll tell you what needs to be added.
Does it still work if the internet goes down?
The Yeelight Pro gateway runs locally. Yeelight officially states that control and automations keep working during internet outages.
Still drawing up plans? WhatsApp us your floor plan or photos of your switch boxes (+60 12-771 0709) and we'll tell you what to prepare. Want to see it in person first? Visit our 1,500 sq ft showroom in Glo Damansara, switch between scenes yourself and compare warm and cool light.